X-ray Flaw Detector
1. General
The frequency-converted and gas-insulated X-Ray machine with ZY-2000 controller, is upgrading generation by NANJING T-BOTA SCIETECH INSTRUMENTS & EQUIPMENT CO.,LTD.
Portable X-ray machine is used to show the internal discontinuity or faults of materials, products or welding from a radiographic image on a film; can be used in the fields of ship-building, mechanical manufacturing, aviation, railroad, pressure vessel, boiler, petroleum, chemical and national defense, performing the non-destructive testing, especially at the construction site or high above the ground applications. Besides of its advantages of small size, light weight, easy to use, simple operation and self-troubleshooting, this machine has excellent performance of strongly interference-free capability, good working stability and operating reliability.
In this series of products, the X-ray generator is furnished with SF6 gas as an insulation, electric fan for forced cooling, the controller is equipped with the advanced microprocessor controlling system, SCR modules for voltage regulation, converting modules to control the primary and secondary side of the SCR as well as the advanced electronic circuits of voltage & current stabilization and interference-free .Thus, the performance of the complete equipment has been improved remarkly!
2.Technical Data
1. General
The frequency-converted and gas-insulated X-Ray machine with ZY-2000 controller, is upgrading generation by NANJING T-BOTA SCIETECH INSTRUMENTS & EQUIPMENT CO.,LTD.
Portable X-ray machine is used to show the internal discontinuity or faults of materials, products or welding from a radiographic image on a film; can be used in the fields of ship-building, mechanical manufacturing, aviation, railroad, pressure vessel, boiler, petroleum, chemical and national defense, performing the non-destructive testing, especially at the construction site or high above the ground applications. Besides of its advantages of small size, light weight, easy to use, simple operation and self-troubleshooting, this machine has excellent performance of strongly interference-free capability, good working stability and operating reliability.
In this series of products, the X-ray generator is furnished with SF6 gas as an insulation, electric fan for forced cooling, the controller is equipped with the advanced microprocessor controlling system, SCR modules for voltage regulation, converting modules to control the primary and secondary side of the SCR as well as the advanced electronic circuits of voltage & current stabilization and interference-free .Thus, the performance of the complete equipment has been improved remarkly!
2.Technical Data
Classify | Model |
Tube voltage (KV) |
Capacity (KW) |
Focus Size (mm) |
Max. penetrate A3 steel (mm) |
Glass tube Directional 40° |
XXQ-1005 | 40-100 | >1.0 | 1.0*1.0 | 8 |
XXQ-1605 | 60-160 | >1.5 | 1.5*1.5 | 20 | |
XXQ-2005 | 80-200 | >2.0 | 1.5*1.5 | 29 | |
XXQ-2505 | 130-250 | >2.5 | 2.0*2.0 | 39 | |
XXQ-3005 | 150-300 | >3.0 | 2.5*2.5 | 49 | |
XXQ-3505 | 250-350 | >3.5 | 2.5*2.5 | 59 | |
Glass tube Panoramic with flat Target 360°*25° |
XXH-1605 | 60-160 | >1.5 | 1.0*2.0 | 18 |
XXH(GH)-2005 | 80-200 | >2.0 | 1.0*2.4 | 26 | |
XXH(GH)-2505 | 130-250 | >2.5 | 1.0*2.4 | 36 | |
XXH-3005 | 150-300 | >3.0 | 1.0*3.4 | 46 | |
XXH-3505 | 250-350 | >3.5 | 1.0*3.4 | 56 | |
Glass tube panoramic with cone Target 360°*40° |
XXHA-1005 | 40-100 | >1.0 | 1.0*2.0 | 4 |
XXHA-1605 | 60-160 | >1.5 | 1.0*2.5 | 15 | |
XXHA-2005 | 80-200 | >2.0 | 1.0*2.5 | 24 | |
XXHA-2505 | 130-250 | >2.5 | 1.0*2.5 | 34 | |
XXHA-3005 | 150-300 | >3.0 | 1.0*3.5 | 40 | |
XXHA-3505 | 250-350 | >3.5 | 1.0*3.5 | 50 | |
Ceramic tube Directional 40° |
XXG-1605 | 60-160 | >1.5 | 1.5*1.5 | 20 |
XXG-2005 | 80-200 | >2.0 | 1.5*1.5 | 29 | |
XXG-2505 | 130-250 | >2.5 | 2.0*2.0 | 39 | |
XXG-3005 | 150-300 | >3.0 | 2.5*2.5 | 49 | |
XXG-3505 | 250-350 | >3.5 | 2.5*2.5 | 59 | |
Tube Current | 5mA | ||||
Power Supply | AC220V ±10% 50HZ | ||||
Controller Size | 367×320×164(mm) | ||||
Insulating | SF6 gas | ||||
Working Temperature |
-25°~ +40° | ||||
Humidity | ≤85% | ||||
Standard Condition |
1. Focus to Film : 600mm 2. Time of exposure :5min 3. Film :Kodak, intensified by double lead foil. 4. Treatment in the darkroom : temperature 20±2ºC, 5min ,Density ≥1.5 |
||||
Safe Pressure | 0.35-0.50 MPa(Prohibition of use when it is lower than 0.35 MPa) |